“I had known George for some six weeks or so before I discovered that he had suffered a leg amputation and was wearing a prosthesis. I had noticed a slight limp but had assumed that it was a temporary sports injury or something similar. Over the years he engaged in windsurfing, scuba diving, water skiing, cycling and played golf (usually in charity tournaments). He did some gardening and all the house maintenance. During our marriage we bought three period houses which he completely renovated himself. This was work that he really enjoyed because of his engineering background. He also used to hang the pub signs for Grays Breweries himself which meant climbing ladders with the signs and the tools necessary to fix them.”
“Wearing this. Liner cracking. He has had abscess over the popliteal region … liner split, foot noisy. Adjust socket, silence foot. In terrible state – would be BER [beyond economic repair] soon”
“11. …. Again, in accordance with my usual practice, I would have checked the alignment, and observed the client as he walked up and down. I would have been anxious to ensure that, firstly the fit of the socket was correct and the suspension was secure. Secondly, I would have checked that the prosthesis was aligned correctly to his footwear and the length of the leg was correct. Delivery would have only taken place if both myself and the deceased were satisfied with the limb. 12. If, at the fitting stage, the deceased had any specific concerns regarding the limb, it would have been recorded in the notes. If, however, the original length had been too long, and had been adjusted at the fitting stage, this would not have been recorded in the notes, as this formed part and parcel of the usual fitting procedure.”
“Fitting OK. Finish off. To collect 25.7.95.”
“9/88 … No Longer Fits – Request 2nd Otto Bock”
“”7/95 limb in “tatty” condition, socket loose – cuff worn. Limb pitches forward. Likes Otto Bock limb. … Limb pitches forward due to change of heel height. Leg in general poor condition.”
“10. Thus, subjectively, the deceased felt that the 1995 limb was in a tatty condition. He complained that the socket was loose, and the cuff was worn, and, as a result the limb was pitching forward. My objective assessment accorded with that of the deceased. I agreed that, in general, the leg was in poor condition and noted that the limb pitched forward due to a change of the deceased’s heel height. The fact that the socket was loose implied that the lining had been compressed from its original thickness of around ¼”, to around ⅛”
“Once the Evaluation Unit had been removed from the existing 1995 limb, it was re-aligned to its original modification, with new lining, a new cuff and new stockings. None of these would have affected the limb length.”
“Socket comfortable. Foot action felt strange. Likes shock absorber. Heel wedge on dynamic foot too soft causing poor gait. All other aspects OK. Foot changed from Bock Dynamic to Quantum Truestep. Then all OK.”
“Patient attended … Unable to wear supracondylar [1998] limb. The fit of this limb is good but he does not like the “insecurity” of the supracondylar suspension. Cast + measured today for Iceross skt. Minor repairs to ’95 limb.”
“…Fitted well. Trimlines adjusted. Patient found this comfortable to wear. Walking well. Del. Satisfactory.”
“… I remember on one evening walking back with them from the theatre to their hotel. This is approximately a five-minute walk but I noticed that my father seemed uncomfortable. He commented that his back and hips were aching and when I asked him why he said that he was trying to wear in a new prosthesis. I encouraged him to continue wearing the new leg if he could, believing his backache to be a teething problem with the new prosthesis, which would hopefully resolve during his holiday.”
“- it explains why he referred to it as his “new” limb: it was; - there would have been a need to wear it in; - it is consistent with notes of difficulties with the 1998 limb; - it explains why he wanted to persist with it, because it was the latest technology, and he had been excited by its feel when first trying it; - the 1998 limb had a feature (Total Shock absorber), which was liable to be associated with backache, according to Mr Wade; - following return home, he returned to wearing the 1995 limb, with which he was comfortable and familiar.”
“24. … We had an extending aluminium ladder which he carried to the front of the house. The ladder had a bar at the bottom to stabilise it. He was wearing trainers, which enabled him to secure his feet on the rungs of the ladder. 25. There are three windows on the wall and the creeper was growing from the left hand side when facing it. It was a creeping hydrangea and it had grown across the left hand window and on to the wall beyond. It had not extended as far as the middle window. George began by placing the ladder to remove the creeper from the wall between the left hand and middle windows. He did this by placing the ladder immediately to the right of the French windows on the ground floor. I watched him cut back the shrub from the guttering and down by about three courses of bricks using a pair of secateurs. This took about 10 minutes and after he had done that he came down the ladder, moved it across to the left and then went up again to remove the creeper from the left hand window where it had been growing across the glass and around the window frame. He placed the ladder immediately to the left of the French windows. He then spent another ten minutes removing the creeper from around the window and from across the glass. After he had removed most of it, he spoke to me from the top of the ladder and we discussed whether or not we should remove it altogether. However we decided to have a cup of tea. He said that he would only be a couple of minutes or so more and therefore I went into the house to put the kettle on. This was about 16.00. 26. Within a couple of minutes I realised that it seemed very quiet outside. I went out again and called but there was no answer. As I went around the house I saw him lying with his left arm straight out and his face straight down on the ground immediately to the left of the French windows. In fact he was lying where the foot of the ladder had been. His amputated leg was bent at the knee at right angles. His left leg was straight. His right hand was flat on the ground. The ladder was lying across his lower back. I cannot remember what part of the ladder. I thought he was dead. I ran to him and could see no sign of life. I then ran indoors and dialled 999. The emergency services called their air support and George was taken to Colchester General Hospital.”
“7/95 limb… wearing 2 socks Patient lost weight (Therefore) line socket for 1 sock & set upright in shoe.”
“I took George to the appointment and we saw the fitter who we had seen on the previous occasion. He said that he remembered the previous visit and after watching George walk up and down he said that he thought he had made progress. I said that I was concerned about George’s walking and I told him that his physiotherapist thought that the prosthesis was 3½ inches too long. He replied “That’s nonsense. If that was the case he would not be able to walk at all”
“… Physio phoned & said that limb was 3.5 inches long. C/E after standing on limb (wearing) slipper it was decided to shorten limb 3cm. Adjust cuff sus(pension).”
“10. When I reviewed the deceased, I agreed that the limb should be shortened by 3 cms, but I see from the worksheet that it was actually adjusted by 2.2 cms. The fact that this adjustment was indicated does not mean that the limb was too long, but simply reflects the fact that, as a result of sustaining damage, the deceased’s brain could not send appropriate signals to the nerve impulses that govern walking, and so the deceased dragged rather than bent his knee when walking. He could not lift his leg to clear the ground. It is fairly routine practice to shorten the limb during the rehabilitation process so that the client can swing the leg through when walking, rather than raising and bending it in the normal manner. The limb was not too long in any absolute sense. 11. As far as I was concerned, this adjustment had satisfactorily dealt with the issue. However, I saw the deceased again on2nd February 2001 together with the physiotherapist from DSC, Ann Roberts, and a physiotherapist from the Homerton Hospital. Again the physiotherapist was concerned by the leg length. At that appointment, I did not make any adjustments to the limb length, as I did not consider any further adjustment was required.”
“… the patient will be asked to stand and the static length and alignment of the limb will be checked. This is usually done by a combination of feel and observation, although some prosthetists will use tape measures or rarely a spirit level. At this point the patient is asked to walk between the parallel bars and asked how the limb feels. The prosthetist will also be checking for movement within the socket and dynamic alignment of the limb as well as assessing the person’s gait. Adjustments may or may not be required on the basis of feedback and comments from the amputee and findings of the prosthetist. This process will continue until both amputee and prosthetist are satisfied.”